Software Library API naibrd 1.62
See all documentation at naii.docs.com
Built-in Test Functions

Functions

NAIBRDFUNC nai_status_t NAIAPI naibrd_DT_CheckPowerOnBITComplete (int32_t cardIndex, int32_t module, bool_t *p_outpbitComplete)
 Retrieves the Power-On BIT (PBIT) status (complete or incomplete) for the specified module. The PBIT result will be in the BIT status register.
 

Detailed Description


Function Documentation

◆ naibrd_DT_CheckPowerOnBITComplete()

NAIBRDFUNC nai_status_t NAIAPI naibrd_DT_CheckPowerOnBITComplete ( int32_t cardIndex,
int32_t module,
bool_t * p_outpbitComplete )

Retrieves the Power-On BIT (PBIT) status (complete or incomplete) for the specified module. The PBIT result will be in the BIT status register.

Note
This feature is only available on the DT1, DT2, DT4 & DT5.

Feature supported in BM Version >= 2.6

Parameters
cardIndex: (Input) Logical Card Index assigned to connection with the NAI_BOARD (0 - NAI_MAX_CARDS-1).
module: (Input) Module Number of the module to access (1 - [max modules for board]).
p_outpbitComplete: (Output) NAI_TRUE = PBIT complete, NAI_FALSE = PBIT not complete.
Returns
  • NAI_SUCCESS
  • NAI_ERROR_INVALID_CARD when invalid card parameter is specified.
  • NAI_ERROR_INVALID_MODULE when invalid module parameter is specified.
  • NAI_ERROR_NOT_OPEN when handle to board is invalid.
  • NAI_ERROR_NOT_SUPPORTED when the module does not support Power-On BIT.